Export limit exceeded: 55519 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (55519 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-38796 1 Redhat 5 Enterprise Linux, Rhel Aus, Rhel E4s and 2 more 2026-04-15 5.9 Medium
EDK2 contains a vulnerability in the PeCoffLoaderRelocateImage(). An Attacker may cause memory corruption due to an overflow via an adjacent network. A successful exploit of this vulnerability may lead to a loss of Confidentiality, Integrity, and/or Availability.
CVE-2024-51555 2026-04-15 10 Critical
Default Credentail vulnerabilities allows access to an Aspect device using publicly available default credentials since the system does not require the installer to change default credentials.  Affected products: ABB ASPECT - Enterprise v3.07.02; NEXUS Series v3.07.02; MATRIX Series v3.07.02
CVE-2024-51562 1 Freebsd 1 Freebsd 2026-04-15 6.5 Medium
The NVMe driver function nvme_opc_get_log_page is vulnerable to a buffer over-read from a guest-controlled value.
CVE-2024-51565 1 Freebsd 1 Freebsd 2026-04-15 6.5 Medium
The hda driver is vulnerable to a buffer over-read from a guest-controlled value.
CVE-2024-51566 1 Freebsd 1 Freebsd 2026-04-15 6.5 Medium
The NVMe driver queue processing is vulernable to guest-induced infinite loops.
CVE-2024-3871 2026-04-15 9.8 Critical
The Delta Electronics DVW-W02W2-E2 devices expose a web administration interface to users. This interface implements multiple features that are affected by command injections and stack overflows vulnerabilities. Successful exploitation of these flaws would allow remote unauthenticated attackers to gain remote code execution with elevated privileges on the affected devices. This issue affects DVW-W02W2-E2 through version 2.5.2.
CVE-2025-43880 2026-04-15 N/A
Inefficient regular expression complexity issue exists in GROWI prior to v7.1.6. If exploited, a logged-in user may cause a denial of service (DoS) condition.
CVE-2024-38658 1 Fujielectric 2 V-server, V-server Lite 2026-04-15 7.8 High
There is an Out-of-bounds read vulnerability in V-Server (v4.0.19.0 and earlier) and V-Server Lite (v4.0.19.0 and earlier). If a user opens a specially crafted file, information may be disclosed and/or arbitrary code may be executed.
CVE-2025-5124 2026-04-15 8.1 High
A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords".
CVE-2025-26409 2026-04-15 6.8 Medium
A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1.
CVE-2024-37816 2026-04-15 4.2 Medium
Quectel EC25-EUX EC25EUXGAR08A05M1G was discovered to contain a stack overflow.
CVE-2024-5178 2026-04-15 4.9 Medium
ServiceNow has addressed a sensitive file read vulnerability that was identified in the Washington DC, Vancouver, and Utah Now Platform releases. This vulnerability could allow an administrative user to gain unauthorized access to sensitive files on the web application server. The vulnerability is addressed in the listed patches and hot fixes, which were released during the June 2024 patching cycle. If you have not done so already, we recommend applying security patches relevant to your instance as soon as possible.
CVE-2024-37795 1 Cvc5 1 Cvc5 2026-04-15 7.5 High
A segmentation fault in CVC5 Solver v1.1.3 allows attackers to cause a Denial of Service (DoS) via a crafted SMT-LIB input file containing the `set-logic` command with specific formatting errors.
CVE-2024-37676 1 Htop 1 Htop 2026-04-15 8.4 High
An issue in htop-dev htop v.2.20 allows a local attacker to cause an out-of-bounds access in the Header_populateFromSettings function.
CVE-2025-31329 2026-04-15 6.2 Medium
SAP NetWeaver is vulnerable to an Information Disclosure vulnerability caused by the injection of malicious instructions into user configuration settings. An attacker with administrative privileges can craft these instructions so that when accessed by the victim, sensitive information such as user credentials is exposed. These credentials may then be used to gain unauthorized access to local or adjacent systems. This results in high impact to Confidentiality, with no significant effect on Integrity or Availability.
CVE-2025-26408 2026-04-15 6.1 Medium
The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device's firmware. All known versions are affected.
CVE-2025-26278 2026-04-15 7.5 High
A prototype pollution in the lib.set function of dref v0.1.2 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload.
CVE-2025-24812 2026-04-15 6.5 Medium
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0) (All versions < V4.7). Affected devices do not process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
CVE-2024-39018 1 Harvey-woo 1 Key-serializer 2026-04-15 6.3 Medium
harvey-woo cat5th/key-serializer v0.2.5 was discovered to contain a prototype pollution via the function "query". This vulnerability allows attackers to execute arbitrary code or cause a Denial of Service (DoS) via injecting arbitrary properties.
CVE-2025-59109 1 Dormakaba 1 Registration Unit 9002 2026-04-15 N/A
The dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi).