Export limit exceeded: 23826 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (23826 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-50475 | 1 Russound | 1 Mbx Pre D67f | 2026-04-15 | 9.8 Critical |
| An OS command injection vulnerability exists in Russound MBX-PRE-D67F firmware version 3.1.6, allowing unauthenticated attackers to execute arbitrary commands as root via crafted input to the hostname parameter in network configuration requests. This vulnerability stems from improper neutralization of special elements used in an OS command within the network configuration handler, enabling remote code execution with the highest privileges. | ||||
| CVE-2023-22351 | 1 Ieisystem | 1 Uefi Firmware | 2026-04-15 | 6.1 Medium |
| Out-of-bounds write in UEFI firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. | ||||
| CVE-2025-54415 | 2026-04-15 | N/A | ||
| dag-factory is a library for Apache Airflow® to construct DAGs declaratively via configuration files. In versions 0.23.0a8 and below, a high-severity vulnerability has been identified in the cicd.yml workflow within the astronomer/dag-factory GitHub repository. The workflow, specifically when triggered by pull_request_target, is susceptible to exploitation, allowing an attacker to execute arbitrary code within the GitHub Actions runner environment. This misconfiguration enables an attacker to establish a reverse shell, exfiltrate sensitive secrets, including the highly-privileged GITHUB_TOKEN, and ultimately gain full control over the repository. This is fixed in version 0.23.0a9. | ||||
| CVE-2021-47745 | 1 Cypress | 1 Ctm-200 | 2026-04-15 | 8.8 High |
| Cypress Solutions CTM-200 2.7.1 contains an authenticated command injection vulnerability in the firmware upgrade script that allows remote attackers to execute shell commands. Attackers can exploit the 'fw_url' parameter in the ctm-config-upgrade.sh script to inject and execute arbitrary commands with root privileges. | ||||
| CVE-2024-43648 | 2026-04-15 | 8.8 High | ||
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2021-35402 | 1 Prolink | 1 Prc2402m | 2026-04-15 | 10 Critical |
| PROLiNK PRC2402M 20190909 before 2021-06-13 allows live_api.cgi?page=satellite_list OS command injection via shell metacharacters in the ip parameter (for satellite_status). | ||||
| CVE-2021-47775 | 1 Litexmedia | 1 Youtube Video Grabber | 2026-04-15 | 8.4 High |
| YouTube Video Grabber, now referred to as YouTube Downloader, 1.9.9.1 contains a buffer overflow vulnerability that allows attackers to execute arbitrary code by overwriting the Structured Exception Handler. Attackers can craft a malicious payload of 712 bytes with SEH manipulation to trigger a bind shell connection on a specified local port. | ||||
| CVE-2021-47774 | 1 Kingdia | 1 Cd Extractor | 2026-04-15 | 9.8 Critical |
| Kingdia CD Extractor 3.0.2 contains a buffer overflow vulnerability in the registration name field that allows attackers to execute arbitrary code. Attackers can craft a malicious payload exceeding 256 bytes to overwrite Structured Exception Handler and gain remote code execution through a bind shell. | ||||
| CVE-2021-33633 | 2026-04-15 | 7.3 High | ||
| Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in openEuler aops-ceres on Linux allows Command Injection. This vulnerability is associated with program files ceres/function/util.Py. This issue affects aops-ceres: from 1.3.0 through 1.4.1. | ||||
| CVE-2021-47747 | 2026-04-15 | 8.8 High | ||
| meterN 1.2.3 contains an authenticated remote code execution vulnerability in admin_meter2.php and admin_indicator2.php scripts. Attackers can exploit the 'COMMANDx' and 'LIVECOMMANDx' POST parameters to execute arbitrary system commands with administrative privileges. | ||||
| CVE-2023-1082 | 2026-04-15 | 8.8 High | ||
| An remote attacker with low privileges can perform a command injection which can lead to root access. | ||||
| CVE-2021-47667 | 1 Zend | 1 Zendto | 2026-04-15 | 10 Critical |
| An OS command injection vulnerability in lib/NSSDropoff.php in ZendTo 5.24-3 through 6.x before 6.10-7 allows unauthenticated remote attackers to execute arbitrary commands via shell metacharacters in the tmp_name parameter when dropping off a file via a POST /dropoff request. | ||||
| CVE-2024-43649 | 2026-04-15 | 8.8 High | ||
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | ||||
| CVE-2024-43650 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-43651 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). | ||||
| CVE-2024-43652 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43654 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-45769 | 1 Redhat | 5 Enterprise Linux, Rhel Aus, Rhel E4s and 2 more | 2026-04-15 | 5.5 Medium |
| A vulnerability was found in Performance Co-Pilot (PCP). This flaw allows an attacker to send specially crafted data to the system, which could cause the program to misbehave or crash. | ||||
| CVE-2025-10441 | 1 D-link | 3 Di-8003g, Di-8100g, Di-8200g | 2026-04-15 | 6.3 Medium |
| A vulnerability was found in D-Link DI-8100G, DI-8200G and DI-8003G 17.12.20A1/19.12.10A1. Affected by this issue is the function sub_433F7C of the file version_upgrade.asp of the component jhttpd. The manipulation of the argument path results in os command injection. The attack may be launched remotely. The exploit has been made public and could be used. | ||||