Export limit exceeded: 23820 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (23820 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-43778 1 Takenaka Engineering 9 Ahd04t-a Firmware, Ahd08t-a Firmware, Ahd16t-a Firmware and 6 more 2026-04-15 8.8 High
OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-42503 1 Arubanetworks 1 Arubaos 2026-04-15 7.2 High
Authenticated command execution vulnerability exist in the ArubaOS command line interface (CLI). Successful exploitation of this vulnerabilities result in the ability to run arbitrary commands as a priviledge user on the underlying operating system.
CVE-2024-42502 1 Arubanetworks 1 Arubaos 2026-04-15 7.2 High
Authenticated command injection vulnerability exists in the ArubaOS command line interface. Successful exploitation of this vulnerability result in the ability to inject shell commands on the underlying operating system.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2025-68922 1 Openops 1 Openops 2026-04-15 7.4 High
OpenOps before 0.6.11 allows remote code execution in the Terraform block.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2025-1883 2026-04-15 7.8 High
Out-Of-Bounds Write vulnerability exists in the OBJ file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025. This vulnerability could allow an attacker to execute arbitrary code while opening a specially crafted OBJ file.
CVE-2025-20014 1 Myscada 1 Mypro Manager 2026-04-15 9.8 Critical
mySCADA myPRO does not properly neutralize POST requests sent to a specific port with version information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system.
CVE-2025-20016 2026-04-15 7.2 High
OS command injection vulnerability exists in network storage servers STEALTHONE D220/D340/D440 provided by Y'S corporation. A user with an administrative privilege who logged in to the web management page of the affected product may execute an arbitrary OS command.
CVE-2024-33218 1 Asus 1 Usb3.0 Boost Storage Driver 2026-04-15 7.8 High
An issue in the component AsUpIO64.sys of ASUSTeK Computer Inc ASUS USB 3.0 Boost Storage Driver 5.30.20.0 allows attackers to escalate privileges and execute arbitrary code via sending crafted IOCTL requests.
CVE-2025-20055 2026-04-15 9.8 Critical
OS command injection vulnerability exists in network storage servers STEALTHONE D220/D340 provided by Y'S corporation. An attacker who can access the affected product may execute an arbitrary OS command.
CVE-2025-22469 1 Sato 4 Cl4nx-j Plus, Cl4nx Plus, Cl6nx-j Plus and 1 more 2026-04-15 N/A
OS command injection vulnerability exists in CL4/6NX Plus and CL4/6NX-J Plus (Japan model) with the firmware versions prior to 1.15.5-r1. An arbitrary OS command may be executed on the system with a certain non-administrative user privilege.
CVE-2025-22495 2026-04-15 8.4 High
An improper input validation vulnerability was discovered in the NTP server configuration field of the Network-M2 card. This could result in an authenticated high privileged user having the ability to execute arbitrary commands. The vulnerability has been resolved in the version 3.0.4. Note - Network-M2 has been declared end-of-life in early 2024 and Network-M3 has been released as a fit-and-functional replacement.
CVE-2025-41427 1 Elecom 3 Wrc-x3000gs, Wrc-x3000gsa, Wrc-x3000gsn 2026-04-15 N/A
WRC-X3000GS, WRC-X3000GSA, and WRC-X3000GSN contain an improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability in Connection Diagnostics page. If a remote authenticated attacker sends a specially crafted request to the affected product, an arbitrary OS command may be executed.
CVE-2025-41413 2026-04-15 7.8 High
Fuji Electric Smart Editor is vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code.
CVE-2024-32850 1 Seiko-sol 2 Skybridge Basic Mb-a130 Firmware, Skybridge Mb-a110 Firmware 2026-04-15 9.8 Critical
Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
CVE-2024-2742 2026-04-15 6.4 Medium
Operating system command injection vulnerability in Planet IGS-4215-16T2S, affecting firmware version 1.305b210528. An authenticated attacker could execute arbitrary code on the remote host by exploiting IP address functionality.
CVE-2024-27172 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 9.8 Critical
Remote Command program allows an attacker to get Remote Code Execution. As for the affected products/models/versions, see the reference URL.