| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Uncontrolled resource consumption in HTTP/2 allows an unauthorized attacker to deny service over a network. |
| FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to version 1.11.1, mod_verto's WebSocket frame loop intercepts a #-prefixed speed-test protocol (#SPU / #SPB / #SPE) before any authentication check. The declared payload size in #SPU was parsed with atoi() and only rejected non-positive values, so an unauthenticated peer could request up to INT_MAX bytes. The server then wrote roughly size * 10 bytes back during the download phase, on the order of 20 GB per request, yielding strong outbound bandwidth amplification from a short request. This issue has been patched in version 1.11.1. |
| An uncaught exception in the /application/job/update/{id} endpoint of FastapiAdmin v2.2.0 allows authenticated attackers with the module_task:job:update permission to cause a Denial of Service (DoS) via manipulating the func field of scheduled tasks. |
| CAI Content Credentials versions c2pa-web@0.7.0, c2pa-v0.78.2 and earlier are affected by an Uncontrolled Resource Consumption vulnerability that could lead to application denial-of-service. An attacker could exploit this vulnerability to exhaust system resources, resulting in an application denial-of-service condition. Exploitation of this issue does not require user interaction. |
| CAI Content Credentials versions c2pa-web@0.7.0, c2pa-v0.78.2 and earlier are affected by an Uncontrolled Resource Consumption vulnerability that could lead to application denial-of-service. An attacker could exploit this vulnerability to exhaust system resources, resulting in an application denial-of-service condition. Exploitation of this issue does not require user interaction. |
| CAI Content Credentials versions c2pa-web@0.7.0, c2pa-v0.78.2 and earlier are affected by an Uncontrolled Resource Consumption vulnerability that could lead to application denial-of-service. An attacker could exploit this vulnerability to exhaust system resources, resulting in an application denial-of-service condition. Exploitation of this issue does not require user interaction. |
| CAI Content Credentials versions c2pa-web@0.7.0, c2pa-v0.78.2 and earlier are affected by an Uncontrolled Resource Consumption vulnerability that could lead to application denial-of-service. An attacker could exploit this vulnerability to exhaust system resources, resulting in an application denial-of-service condition. Exploitation of this issue does not require user interaction. |
| Spring MVC and WebFlux applications are vulnerable to Denial of Service (DoS) attacks when resolving static resources.
Affected versions:
Spring Framework 7.0.0 through 7.0.7; 6.2.0 through 6.2.18; 6.1.0 through 6.1.27; 5.3.0 through 5.3.48. |
| Windows Remote Desktop Services Denial of Service Vulnerability |
| Windows Remote Desktop Gateway (RD Gateway) Denial of Service Vulnerability |
| Microsoft Message Queuing (MSMQ) Denial of Service Vulnerability |
| Windows Remote Desktop Services Denial of Service Vulnerability |
| Windows Hyper-V Denial of Service Vulnerability |
| Windows Online Certificate Status Protocol (OCSP) Server Denial of Service Vulnerability |
| Microsoft Simple Certificate Enrollment Protocol Denial of Service Vulnerability |
| BranchCache Denial of Service Vulnerability |
| Microsoft Simple Certificate Enrollment Protocol Denial of Service Vulnerability |
| Internet Small Computer Systems Interface (iSCSI) Denial of Service Vulnerability |
| BranchCache Denial of Service Vulnerability |
| A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (All versions), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (All versions >= V4.2.0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (All versions), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (All versions < V1.3), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (All versions < V6.0.1), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (All versions >= V4.2.0 < V4.2.5), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (All versions < V4.2.2), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (All versions), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (All versions < V6.0.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (All versions >= V4.2.0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (All versions < V6.0.0). Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state.
This could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation. |