| Zope AccessControl provides a general security framework for use in Zope. In affected versions anonymous users can delete the user data maintained by an `AccessControl.userfolder.UserFolder` which may prevent any privileged access. This problem has been fixed in version 7.2. Users are advised to upgrade. Users unable to upgrade may address the issue by adding `data__roles__ = ()` to `AccessControl.userfolder.UserFolder`. |
| Improper access control for some Intel(R) PresentMon before version 2.3.1 within Ring 3: User Applications may allow a denial of service. Network adversary with a privileged user combined with a high complexity attack may enable denial of service. This result may potentially occur via adjacent access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (low) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. |
| A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software.
Other related CVE's are CVE-2025-14096 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required configuration for Exposure:
Physical access to the analyzer is needed.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication. Note:
CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems. |
| OpenObserve is a cloud-native observability platform. A vulnerability in the user management endpoint `/api/{org_id}/users/{email_id}` allows an "Admin" role user to remove a "Root" user from the organization. This violates the intended privilege hierarchy, enabling a non-root user to remove the highest-privileged account. Due to insufficient role checks, the `remove_user_from_org` function does not prevent an "Admin" user from removing a "Root" user. As a result, an attacker with an "Admin" role can remove critical "Root" users, potentially gaining effective full control by eliminating the highest-privileged accounts. The `DELETE /api/{org_id}/users/{email_id}` endpoint is affected. This issue has been addressed in release version `0.14.1` and all users are advised to upgrade. There are no known workarounds for this vulnerability. |
| A vulnerability was found in INSTAR 2K+ and 4K 3.11.1 Build 1124. This issue affects some unknown processing of the component UART Interface. The manipulation leads to improper physical access control. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. |
| A vulnerability has been found in zlt2000 microservices-platform up to 6.0.0 and classified as problematic. This vulnerability affects unknown code of the file /actuator of the component Spring Actuator Interface. The manipulation leads to information disclosure. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. |
| A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16 and classified as critical. Affected by this issue is some unknown functionality of the file /priv/production/production.html of the component Production Tools. The manipulation leads to improper access controls. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability, which was classified as critical, has been found in LB-LINK BL-AC1900, BL-AC2100_AZ3, BL-AC3600, BL-AX1800, BL-AX5400P and BL-WR9000 up to 20250702. This issue affects the function bs_GetManPwd in the library libblinkapi.so of the file /cgi-bin/lighttpd.cgi. The manipulation leads to information disclosure. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as critical was found in LB-LINK BL-AC1900, BL-AC2100_AZ3, BL-AC3600, BL-AX1800, BL-AX5400P and BL-WR9000 up to 20250702. This vulnerability affects the function bs_GetHostInfo in the library libblinkapi.so of the file /cgi-bin/lighttpd.cgi. The manipulation leads to information disclosure. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability in EdgeConnect SD-WAN ECOS could allow an authenticated remote threat actor with admin privileges to access sensitive unauthorized system files. Under certain conditions, this could lead to exposure and exfiltration of sensitive information. |
| The s2Member – Best Membership Plugin for All Kinds of Memberships, Content Restriction Paywalls & Member Access Subscriptions plugin for WordPress is vulnerable to Information Exposure in all versions up to, and including, 230815 via the API. This makes it possible for unauthenticated attackers to see the contents of those posts and pages. |
| Incorrect access control in Ullu (Android version v2.9.929 and IOS version v2.8.0) allows attackers to bypass parental pin feature via unspecified vectors. |
| DASAN GPON ONU H660WM H660WMR210825 is susceptible to improper access control under its default settings. Attackers can exploit this vulnerability to gain unauthorized access to sensitive information and modify its configuration via the UPnP protocol WAN sides without any authentication. |
| A vulnerability classified as critical has been found in youyiio BeyongCms 1.6.0. Affected is an unknown function of the file /admin/theme/Upload.html of the component Document Management Page. The manipulation of the argument File leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. |
| An issue was discovered in mcp-neo4j 0.3.0 allowing attackers to obtain sensitive information or execute arbitrary commands via the SSE service. NOTE: the Supplier's position is that authentication is not mandatory for MCP servers, and the mcp-neo4j MCP server is only intended for use in a local environment where authentication realistically would not be needed. Also, the Supplier provides middleware to help isolate the MCP server from external access (if needed). |
| There is an Access Control Vulnerability in some HikCentral Professional versions. This could allow an unauthenticated user to obtain the admin permission. |
| A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices with role `user` is affected by incorrect authorization in SNMPv3 View configuration. This could allow an attacker to change the View Type of SNMPv3 Views. |
| A critical severity vulnerability has been identified in the ALPR Manager role of Security Center that could allow attackers to gain administrative access to the Genetec Security Center system. The Genetec engineering team discovered this issue internally. There is currently no evidence that this vulnerability has been exploited in the wild. |