Export limit exceeded: 410007 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (10264 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-15065 | 2026-04-15 | 6.3 Medium | ||
| Exposure of Sensitive Information to an Unauthorized Actor, Missing Encryption of Sensitive Data, Files or Directories Accessible to External Parties vulnerability in Kings Information & Network Co. KESS Enterprise on Windows allows Privilege Escalation, Modify Existing Service, Modify Shared File.This issue affects KESS Enterprise: before *.25.9.19.exe | ||||
| CVE-2025-15117 | 1 Dromara | 1 Sa-token | 2026-04-15 | 3.1 Low |
| A weakness has been identified in Dromara Sa-Token up to 1.44.0. This affects the function ObjectInputStream.readObject of the file SaJdkSerializer.java. Executing manipulation can lead to deserialization. The attack may be launched remotely. This attack is characterized by high complexity. It is indicated that the exploitability is difficult. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2023-25581 | 1 Pac4j | 1 Pac4j | 2026-04-15 | N/A |
| pac4j is a security framework for Java. `pac4j-core` prior to version 4.0.0 is affected by a Java deserialization vulnerability. The vulnerability affects systems that store externally controlled values in attributes of the `UserProfile` class from pac4j-core. It can be exploited by providing an attribute that contains a serialized Java object with a special prefix `{#sb64}` and Base64 encoding. This issue may lead to Remote Code Execution (RCE) in the worst case. Although a `RestrictedObjectInputStream` is in place, that puts some restriction on what classes can be deserialized, it still allows a broad range of java packages and potentially exploitable with different gadget chains. pac4j versions 4.0.0 and greater are not affected by this issue. Users are advised to upgrade. There are no known workarounds for this vulnerability. | ||||
| CVE-2025-61482 | 2 Google, Privacyidea | 2 Android, Privacyidea | 2026-04-15 | 7.2 High |
| Improper handling of OTP/TOTP/HOTP values in NetKnights GmbH privacyIDEA Authenticator v.4.3.0 on Android allows local attackers with root access to bypass two factor authentication. By hooking into app crypto routines and intercepting decryption paths, attacker can recover plaintext secrets, enabling generation of valid one-time passwords, and bypassing authentication for enrolled accounts. | ||||
| CVE-2024-4836 | 2026-04-15 | 7.5 High | ||
| Web services managed by Edito CMS (Content Management System) in versions from 3.5 through 3.25 leak sensitive data as they allow downloading configuration files by an unauthenticated user. The issue in versions 3.5 - 3.25 was removed in releases which dates from 10th of January 2014. Higher versions were never affected. | ||||
| CVE-2021-47759 | 1 Ttyplus | 1 Mtputty | 2026-04-15 | 6.2 Medium |
| MTPutty 1.0.1.21 contains a sensitive information disclosure vulnerability that allows local attackers to view SSH connection passwords through Windows PowerShell process listing. Attackers can run a PowerShell command to retrieve the full command line of MTPutty processes, exposing plaintext SSH credentials. | ||||
| CVE-2021-47741 | 2026-04-15 | 7.5 High | ||
| ZBL EPON ONU Broadband Router V100R001 contains a privilege escalation vulnerability that allows limited administrative users to elevate access by sending requests to configuration endpoints. Attackers can exploit the vulnerability by accessing the configuration backup or password page to disclose the super user password and gain additional privileged functionalities. | ||||
| CVE-2025-15222 | 1 Dromara | 1 Sa-token | 2026-04-15 | 5 Medium |
| A vulnerability has been found in Dromara Sa-Token up to 1.44.0. This issue affects the function ObjectInputStream.readObject of the file SaSerializerTemplateForJdkUseBase64.java. Such manipulation leads to deserialization. The attack can be executed remotely. This attack is characterized by high complexity. The exploitability is assessed as difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-27458 | 1 Hp | 40 Elite Dragonfly Firmware, Elite Dragonfly G2 Firmware, Elite Dragonfly Max Firmware and 37 more | 2026-04-15 | 8.8 High |
| A potential security vulnerability has been identified in the HP Hotkey Support software, which might allow local escalation of privilege. HP is releasing mitigation for the potential vulnerability. Customers using HP Programmable Key are recommended to update HP Hotkey Support. | ||||
| CVE-2021-47726 | 1 Nucom | 1 11n Wireless Router | 2026-04-15 | 7.5 High |
| NuCom 11N Wireless Router 5.07.90 contains a privilege escalation vulnerability that allows non-privileged users to access administrative credentials through the configuration backup endpoint. Attackers can send a crafted HTTP GET request to the backup configuration page with a specific cookie to retrieve and decode the admin password in Base64 format. | ||||
| CVE-2024-22038 | 2026-04-15 | 7.3 High | ||
| Various problems in obs-scm-bridge allows attackers that create specially crafted git repositories to leak information of cause denial of service. | ||||
| CVE-2024-52522 | 1 Rclone | 1 Rclone | 2026-04-15 | 6.8 Medium |
| Rclone is a command-line program to sync files and directories to and from different cloud storage providers. Insecure handling of symlinks with --links and --metadata in rclone while copying to local disk allows unprivileged users to indirectly modify ownership and permissions on symlink target files when a superuser or privileged process performs a copy. This vulnerability could enable privilege escalation and unauthorized access to critical system files, compromising system integrity, confidentiality, and availability. This vulnerability is fixed in 1.68.2. | ||||
| CVE-2024-29216 | 2026-04-15 | 6.1 Medium | ||
| Exposed IOCTL with insufficient access control issue exists in cg6kwin2k.sys prior to 2.1.7.0. By sending a specific IOCTL request, a user without the administrator privilege may perform I/O to arbitrary hardware port or physical address, resulting in erasing or altering the firmware. | ||||
| CVE-2024-39290 | 2026-04-15 | N/A | ||
| Insufficiently protected credentials issue exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent unauthenticated attacker may obtain sensitive information such as a username and its password in the address book. | ||||
| CVE-2024-39334 | 2026-04-15 | 6.5 Medium | ||
| MENDELSON AS4 before 2024 B376 has a client-side vulnerability when a trading partner provides prepared XML data. When a victim opens the details of this transaction in the client, files can be written to the computer on which the client process is running. (The server process is not affected.) | ||||
| CVE-2024-42363 | 1 Zendesk | 1 Samson | 2026-04-15 | 8.8 High |
| Prior to 3385, the user-controlled role parameter enters the application in the Kubernetes::RoleVerificationsController. The role parameter flows into the RoleConfigFile initializer and then into the Kubernetes::Util.parse_file method where it is unsafely deserialized using the YAML.load_stream method. This issue may lead to Remote Code Execution (RCE). This vulnerability is fixed in 3385. | ||||
| CVE-2024-42407 | 2026-04-15 | 8.5 High | ||
| Insertion of Sensitive Information into Log File (CWE-532) in the Gallagher Command Centre Alarm Transmitter feature could allow an authenticated Operator to view some security sensitive information to which they have not been granted access. This issue affects: Command Centre Server 9.10 prior to 9.10.2149 (MR4), 9.00 prior to 9.00.2374 (MR5), 8.90 prior to 8.90.2356 (MR6), all versions of 8.80 and prior. | ||||
| CVE-2024-4369 | 1 Redhat | 1 Openshift | 2026-04-15 | 6.8 Medium |
| An information disclosure flaw was found in OpenShift's internal image registry operator. The AZURE_CLIENT_SECRET can be exposed through an environment variable defined in the pod definition, but is limited to Azure environments. An attacker controlling an account that has high enough permissions to obtain pod information from the openshift-image-registry namespace could use this obtained client secret to perform actions as the registry operator's Azure service account. | ||||
| CVE-2024-43781 | 2026-04-15 | 5.5 Medium | ||
| A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions. | ||||
| CVE-2024-43812 | 1 Kieback\&peter | 10 Ddc4002 Firmware, Ddc4002e Firmware, Ddc4020e Firmware and 7 more | 2026-04-15 | 8.4 High |
| Kieback & Peter's DDC4000 series has an insufficiently protected credentials vulnerability, which may allow an unauthenticated attacker with access to /etc/passwd to read the password hashes of all users on the system. | ||||