| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Hardcoded credentials vulnerability in Trellix ePolicy Orchestrator (ePO) on Premise prior to 5.10 Service Pack 1 Update 2 allows an attacker with admin privileges on the ePO server to read the contents of the orion.keystore file, allowing them to access the ePO database encryption key. This was possible through using a hard coded password for the keystore. Access Control restrictions on the file mean this would not be exploitable unless the user is the system admin for the server that ePO is running on. |
| CWE-798 Use of Hard-coded Credentials |
| The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges. |
| A hardcoded AES key in PMFW may result in a privileged attacker gaining access to the key, potentially resulting in internal debug information leakage. |
| Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1. |
| Use of hard-coded credentials issue exists in ZWX-2000CSW2-HN prior to 0.3.19 and ZWX-2000CS2-HN firmware all versions. If this vulnerability is exploited, an attacker may tamper with the settings of the device by obtaining the credentials. This vulnerability is caused by an insufficient fix for CVE-2024-39838. |
| A vulnerability classified as critical was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this vulnerability is an unknown functionality of the component Device Pairing. The manipulation leads to hard-coded credentials. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as problematic was found in Audi UTR Dashcam 2.0. Affected by this vulnerability is an unknown functionality of the component Video Stream Handler. The manipulation leads to hard-coded credentials. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers. |
| A vulnerability has been discovered in the firmware of Paxton Paxton10 before 4.6 SR6. The firmware file, rootfs.tar.gz, contains hard-coded credentials for the Twilio API. A remote attacker who obtains a copy of the firmware can extract these credentials. This could allow the attacker to gain unauthorized access to the associated Twilio account, leading to information disclosure, potential service disruption, and unauthorized use of the Twilio services. |
| FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system. |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) contains hardcoded API credentials and an OS command injection flaw in its configuration services. The web/API interface accepts HTTP/XML requests authenticated with a fixed vendor credential string and passes user-controlled fields into shell execution contexts without proper argument sanitization. An unauthenticated remote attacker can leverage the hard-coded credential to access endpoints such as /editBlackAndWhiteList and inject shell metacharacters inside XML parameters, resulting in arbitrary command execution as root. The same vulnerable backend is also reachable in some models through a proprietary TCP service on port 4567 that accepts a magic GUID preface and base64-encoded XML, enabling the same command injection sink. Firmware releases from mid-February 2018 and later are reported to have addressed this issue. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-28 UTC. |
| Project AI is a platform designed to create AI agents. Prior to the pre-beta version, a hardcoded API key was present in the source code. This issue has been patched in the pre-beta version. |
| There are several scripts in the web interface that are accessible via undocumented hard-coded credentials. The scripts provide access to additional administrative/debug functionality and are likely intended for debugging during development and provides an additional attack surface. |
| The `/etc/passwd` and `/etc/shadow` files reveal hard-coded password hashes for the operating system "root" user. The credentials are shipped with the update files. There is no option for deleting or changing their passwords for an enduser. An attacker can use the credentials to log into the device. Authentication can be performed via SSH backdoor or likely via physical access (UART shell). |
| Quantum StorNext Web GUI API before 7.2.4 grants access to internal StorNext configuration and unauthorized modification of some software configuration parameters via undocumented user credentials. This affects StorNext RYO before 7.2.4, StorNext Xcellis Workflow Director before 7.2.4, and ActiveScale Cold Storage. |
| The CS5000 Fire Panel is vulnerable due to a hard-coded password that
runs on a VNC server and is visible as a string in the binary
responsible for running VNC. This password cannot be altered, allowing
anyone with knowledge of it to gain remote access to the panel. Such
access could enable an attacker to operate the panel remotely,
potentially putting the fire panel into a non-functional state and
causing serious safety issues. |
| Default credentials were present in the web portal for Airpointer 2.4.107-2, allowing an unauthenticated malicious actor to log in via the web portal |
| UNI-NMS-Lite uses hard-coded credentials that could allow an
unauthenticated attacker to read, manipulate and create entries in the
managed database. |
| UNI-NMS-Lite uses hard-coded credentials that could allow an
unauthenticated attacker to gain administrative privileges to all
UNI-NMS managed devices. |