CVE-2026-27661 1 Siemens 1 Sinec Security Monitor 2026-04-16 4.3 Medium
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application leaks confidential information in metadata, and files such as information on contributors and email address, on `SSM Server`.
CVE-2001-0384 1 Siemens 1 Reliant Unix 2026-04-16 N/A
ppd in Reliant Sinix allows local users to corrupt arbitrary files via a symlink attack in the /tmp/ppd.trace file.
CVE-1999-0017 9 Caldera, Freebsd, Gnu and 6 more 11 Openlinux, Freebsd, Inet and 8 more 2026-04-16 N/A
FTP servers can allow an attacker to connect to arbitrary ports on machines other than the FTP client, aka FTP bounce.
CVE-2006-3907 1 Siemens 1 Speedstream Wireless Router 2026-04-16 N/A
Siemens SpeedStream 2624 allows remote attackers to cause a denial of service (device hang) by sending a crafted packet to the web administrative interface.
CVE-2006-3344 1 Siemens 1 Speedstream Wireless Router 2026-04-16 N/A
Siemens Speedstream Wireless Router 2624 allows local users to bypass authentication and access protected files by using the Universal Plug and Play UPnP/1.0 component.
CVE-2002-1484 1 Siemens 1 Db4web 2026-04-16 9.8 Critical
DB4Web server, when configured to use verbose debug messages, allows remote attackers to use DB4Web as a proxy and attempt TCP connections to other systems (port scan) via a request for a URL that specifies the target IP address and port, which produces a connection status in the resulting error message.
CVE-2005-2424 1 Siemens 1 Santis 50 2026-04-16 N/A
The management interface for Siemens SANTIS 50 running firmware 4.2.8.0, and possibly other products including Ericsson HN294dp and Dynalink RTA300W, allows remote attackers to access the Telnet port without authentication via certain packets to the web interface that cause the interface to freeze.
CVE-2004-2626 1 Siemens 1 S55 2026-04-16 N/A
GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message.
CVE-2002-0122 1 Siemens 1 3568i Wap 2026-04-16 N/A
Siemens 3568i WAP mobile phones allows remote attackers to cause a denial of service (crash) via an SMS message containing unusual characters.
CVE-2003-1464 1 Siemens 2 M45, S45 2026-04-16 N/A
Buffer overflow in Siemens 45 series mobile phones allows remote attackers to cause a denial of service (disconnect and unavailable inbox) via a Short Message Service (SMS) message with a long image name.
CVE-2000-0964 1 Siemens 1 Hinet Lp 2026-04-16 N/A
Buffer overflow in the web administration service for the HiNet LP5100 IP-phone allows remote attackers to cause a denial of service and possibly execute arbitrary commands via a long GET request.
CVE-2003-0190 4 Openbsd, Openpkg, Redhat and 1 more 8 Openssh, Openpkg, Enterprise Linux and 5 more 2026-04-16 N/A
OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack.
CVE-2001-0411 1 Siemens 1 Reliant Unix 2026-04-16 N/A
Reliant Unix 5.44 and earlier allows remote attackers to cause a denial of service via an ICMP port unreachable packet, which causes Reliant to drop all connections to the source address of the packet.
CVE-2020-8177 6 Debian, Fujitsu, Haxx and 3 more 19 Debian Linux, M10-1, M10-1 Firmware and 16 more 2026-04-15 7.8 High
curl 7.20.0 through 7.70.0 is vulnerable to improper restriction of names for files and other resources that can lead too overwriting a local file when the -J flag is used.
CVE-2018-16890 8 Canonical, Debian, F5 and 5 more 11 Ubuntu Linux, Debian Linux, Big-ip Access Policy Manager and 8 more 2026-04-15 7.5 High
libcurl versions from 7.36.0 to before 7.64.0 is vulnerable to a heap buffer out-of-bounds read. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds.
CVE-2019-3822 7 Canonical, Debian, Haxx and 4 more 17 Ubuntu Linux, Debian Linux, Libcurl and 14 more 2026-04-15 9.8 Critical
libcurl versions from 7.36.0 to before 7.64.0 are vulnerable to a stack-based buffer overflow. The function creating an outgoing NTLM type-3 header (`lib/vauth/ntlm.c:Curl_auth_create_ntlm_type3_message()`), generates the request HTTP header contents based on previously received data. The check that exists to prevent the local buffer from getting overflowed is implemented wrongly (using unsigned math) and as such it does not prevent the overflow from happening. This output data can grow larger than the local buffer if very large 'nt response' data is extracted from a previous NTLMv2 header provided by the malicious or broken HTTP server. Such a 'large value' needs to be around 1000 bytes or more. The actual payload data copied to the target buffer comes from the NTLMv2 type-2 response header.
CVE-2026-25656 1 Siemens 3 Sinec-nms, Sinec Nms, User Management Component 2026-04-15 7.8 High
A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3), User Management Component (UMC) (All versions < V2.15.2.1). The affected application permits improper modification of a configuration file by a low-privileged user. This could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with SYSTEM privileges.(ZDI-CAN-28108)
CVE-2024-44087 1 Siemens 1 Automation License Manager 2026-04-15 8.6 High
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification.
CVE-2024-52504 1 Siemens 1 Siprotec 4 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted.
CVE-2011-20002 1 Siemens 3 Simatic, Simatic S7-1200, Simatic S7-1200 Cpu 2026-04-15 7.4 High
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.