Export limit exceeded: 425866 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (55507 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-57375 | 2026-04-15 | 2.4 Low | ||
| Andamiro Pump It Up 20th Anniversary (aka Double X or XX/2019) 1.00.0-2.08.3 allows a physically proximate attacker to cause a denial of service (application crash) via certain deselect actions. | ||||
| CVE-2024-57262 | 1 Pengutronix | 1 Barebox | 2026-04-15 | 7.1 High |
| In barebox before 2025.01.0, ext4fs_read_symlink has an integer overflow for zalloc (adding one to an le32 variable) via a crafted ext4 filesystem with an inode size of 0xffffffff, resulting in a malloc of zero and resultant memory overwrite, a related issue to CVE-2024-57256. | ||||
| CVE-2024-57261 | 1 Pengutronix | 1 Barebox | 2026-04-15 | 7.1 High |
| In barebox before 2025.01.0, request2size in common/dlmalloc.c has an integer overflow, a related issue to CVE-2024-57258. | ||||
| CVE-2024-56139 | 2026-04-15 | N/A | ||
| pdftools is a high level tools to convert PDF files to ePUB formats. In versions up to and including 0.5.0 maliciously crafted epub files can cause a stack overflow leading to a crash. This issue has not yet been addressed and users are advised to avoid untrusted input to their systems. | ||||
| CVE-2024-56083 | 2026-04-15 | 8.1 High | ||
| Cognition Devin before 2024-12-12 provides write access to code by an attacker who discovers the https://vscode-randomly_generated_string.devinapps.com URL (aka the VSCode live share URL) for a specific "Use Devin's Machine" session. For example, this URL may be discovered if a customer posts a screenshot of a Devin session to social media, or publicly streams their Devin session. | ||||
| CVE-2024-5602 | 1 Ni | 1 System Configuration | 2026-04-15 | 7.8 High |
| A stack-based buffer overflow vulnerability due to a missing bounds check in the NI I/O Trace Tool may result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted nitrace file. The NI I/O Trace tool is installed as part of the NI System Configuration utilities included with many NI software products. Refer to the NI Security Advisory for identifying the version of NI IO Trace.exe installed. The NI I/O Trace tool was also previously released as NI Spy. | ||||
| CVE-2024-37997 | 1 Siemens | 2 Jt Open, Plm Xml Sdk | 2026-04-15 | 7.8 High |
| A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2024-55888 | 2026-04-15 | 7.1 High | ||
| Hush Line is an open-source whistleblower management system. Starting in version 0.1.0 and prior to version 0.3.5, the productions server appeared to have been misconfigured and missed providing any content security policy or security headers. This could result in bypassing of cross-site scripting filters. Version 0.3.5 fixed the issue. | ||||
| CVE-2025-1866 | 2026-04-15 | 8.0 High | ||
| Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in warmcat libwebsockets allows Pointer Manipulation, potentially leading to out-of-bounds memory access. This issue affects libwebsockets before 4.3.4 and is present in code built specifically for the Win32 platform. By default, the affected code is not executed unless one of the following conditions is met: LWS_WITHOUT_EXTENSIONS (default ON) is manually set to OFF in CMake. LWS_WITH_HTTP_STREAM_COMPRESSION (default OFF) is manually set to ON in CMake. Despite these conditions, when triggered in affected configurations, this vulnerability may allow attackers to manipulate pointers, potentially leading to memory corruption or unexpected behavior. | ||||
| CVE-2024-55652 | 2026-04-15 | 6.5 Medium | ||
| PenDoc is a penetration testing reporting application. Prior to commit 1d4219c596f4f518798492e48386a20c6e9a2fe6, an attacker can write a malicious docx template containing expressions that escape the JavaScript sandbox to execute arbitrary code on the system. An attacker who can control the contents of the template document is able to execute arbitrary code on the system. By default, only users with the `admin` role are able to create or update templates. Commit 1d4219c596f4f518798492e48386a20c6e9a2fe6 patches the issue. | ||||
| CVE-2024-55564 | 1 Perl | 1 Posix 2028 | 2026-04-15 | 9.8 Critical |
| The POSIX::2008 package before 0.24 for Perl has a potential _execve50c env buffer overflow. | ||||
| CVE-2025-0038 | 1 Amd | 1 Zynq Ultrascale+ | 2026-04-15 | 6.6 Medium |
| In AMD Zynq UltraScale+ devices, the lack of address validation when executing CSU runtime services through the PMU Firmware can allow access to isolated or protected memory spaces resulting in the loss of integrity and confidentiality. | ||||
| CVE-2024-54090 | 2026-04-15 | 5.9 Medium | ||
| A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function. This could allow an attacker with Medium (MED) or higher privileges to cause the device to enter an insecure cold start state. | ||||
| CVE-2024-54015 | 2026-04-15 | 7.5 High | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. | ||||
| CVE-2025-1960 | 2026-04-15 | 9.8 Critical | ||
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface. | ||||
| CVE-2025-13566 | 1 Jarun | 1 Nnn | 2026-04-15 | 3.3 Low |
| A security vulnerability has been detected in jarun nnn up to 5.1. The impacted element is the function show_content_in_floating_window/run_cmd_as_plugin of the file nnn/src/nnn.c. The manipulation leads to double free. An attack has to be approached locally. The identifier of the patch is 2f07ccdf21e705377862e5f9dfa31e1694979ac7. It is suggested to install a patch to address this issue. | ||||
| CVE-2025-13132 | 1 The Browser Company | 1 Dia | 2026-04-15 | 7.4 High |
| This vulnerability allowed a site to enter fullscreen, after a user click, without a full-screen notification (toast) appearing. Without this notification, users could potentially be misled about what site they were on if a malicious site renders a fake UI (like a fake address bar.) | ||||
| CVE-2025-26789 | 2026-04-15 | N/A | ||
| An issue was discovered in Logpoint AgentX before 1.5.0. A vulnerability caused by limited access controls allowed li-admin users to access sensitive information about AgentX Manager in a Logpoint deployment. | ||||
| CVE-2024-3911 | 2026-04-15 | 6.5 Medium | ||
| An unauthenticated remote attacker can deceive users into performing unintended actions due to improper restriction of rendered UI layers or frames. | ||||
| CVE-2024-39129 | 2026-04-15 | 5.3 Medium | ||
| Heap Buffer Overflow vulnerability in DumpTS v0.1.0-nightly allows attackers to cause a denial of service via the function PushTSBuf() at /src/PayloadBuf.cpp. | ||||